common problems

0

Winter central air conditioning how to prevent freezing

A1: In winter, when the temperature in the mainframe room is below 0℃, anti-freezing measures should be taken for the mainframe, chilled water pump, and cooling water pump piping system. 1, the host of anti-freezing: the host condenser, evaporator import and export valves closed, waterproof valve and venting valve open, and then the use of compressed air or nitrogen will be blown out of the residual water; 2, water pump and pipeline antifreeze: keep the freezing/cooling water valve and pipeline open, the lowest...
Continue reading
0

Central air conditioner smells bad when turned on

1, a long time is not with the central air conditioning, summer use, inside the sink is still part of the stock water, these stocks of water due to mold over time, the smell is blown out of the air, this problem, we can set the air conditioning mode of operation for the circulation of the wind mode, open the window, let the air conditioning run for about 30min, you can eliminate the smell. 2, when not in use for a long time, you can let the air conditioner open circulating wind operation...
Continue reading
0

Central air conditioner does not start immediately after shutdown

Central air conditioning is used by the air conditioner to switch on and off control, air conditioning normal operation after turning on the air conditioner, the air conditioner will be able to operate normally in accordance with the selected mode of operation. Air conditioner for whatever reason and shut down, due to the general air conditioner are equipped with a time delay for the shutdown (delay time of about 3min), then this type of air conditioner can be turned on immediately after the shutdown, but need to be after 3min to run. But there is no time delay...
Continue reading
0

Poor heating/cooling of air conditioners

1. Improper use and maintenance Solution: In the winter when using the central air conditioning heating should pay attention to the sealing of the house, observe the outdoor unit with or without frost, ice, do not force hot water for frost and ice, such as trouble should be timely contact with the Tianjin Bote Environmental after-sales department. Encounter failure should stop using and contact a professional central air conditioning repair personnel to check and repair. 2. Fluorine deficiency Solution: central air conditioning suspected...
Continue reading
0

How to perform hot cross cleaning and maintenance of central air conditioning

General use of two years of maintenance once, available non-flammable and non-corrosive gas blowing off the heat exchanger on the accumulation of dust, special harsh environment needs to increase the frequency of cleaning. Cleaning water temperature should not be higher than 40 degrees Celsius, and can not use gasoline and other corrosive, strong solvent cleaning. Check the central air conditioner how to maintain the power supply line, piping insulation sleeve, strapping whether there is broken, loose and other phenomena.
Continue reading